Product information
Details
Automotive On-board diagnostic systems of thesedays have gone a long way toward helping you locate a problem. But those systems aren't perfect and they don't cover everything (most glitches and intermittents). So the real challenge that befuddles most automotive technicians is diagnosing "no-code" trouble. On-board diagnostic systems are engineered with fairly wide set limits for sensors, actuators, connectors and terminals. When a component exceeds its limit consistently, a trouble code is generated. But to keep warranty costs in line, tolerances aren't set to catch all transients, even though they can cause some of your worst headaches. As a result, technicians are finding more and more uses for the oscilloscope - next to the multimeter,the most common troubleshooting tool.
The 1005 Automotive Scope/GMM represents the most powerful and usersatile tool available for troubleshooting automotive electronics since we can track down elusive no-code driveability problems.
Features:
- A 25 Mega-sample/Second (one channel minimum) sample rate for rapid data updates.
- Lab scope signal patterns.
- True RMS Graphing Multimeter (GMM) measurements and graphs.
- A unique "Glitch Snare" mode which captures, displays and optionally saves abnormal signal patterns in the Scope mode of the COMPONENT TESTS only when hey occur.
- Preset tests that enable the user to check the majority of automotive sensors, actuators and systems easily and quickly.
- Powerful built-in reference information for each preset test which includes a test procedure showing how to connect to the circuit, a normal reference signal pattern, heory of operation and troubleshooting tips.
- Menu-driven interface has automatic configurations for most of non-preset tests, so you will find that the instrument is easy-to-use.
- The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
- The Diesel function allows you to set injection pump timing and RPM using the optional Diesel accessories.
- USB interface supports updates for code and data.
Electrical Specification:
Accuracies is given as ±(% of reading + number of least significant digits) at 18°C to 28°C with relative humidity up to 80%, for a period of one year after calibration.
Scope Specifications
Horizontal
- Sample rate : 25 Mega sample/second
- Record length : 1000 Points
- Update rate : Real time, Roll
- Accuracy : ± (0.1 % + 1 pixel)
- Sweep rate : 1 µs to 50 sec in a 1, 2, 5 sequence (Scope mode)
- 5 s to 24 Hours in a 1, 2, 5 sequence (GMM mode)
Vertical
- Band width : DC to 5 MHz ; -3 dB
- Resolution : 8 bit
- Channel : 2 Channel
- Coupling : AC, DC, GND
- Input Impedance : 1 Mohm / 70 pF
- Maximum Input Voltage : 300 V
- Volt/Division : 50 mV to 100 V in a 1, 2, 5 sequence
- Accuracy : ± 3 %
Trigger
- Trigger Source : CH A, CH B, TRIGGER (External trigger)
- Sensitivity (CH A) : < 1.0 div to 5 MHz
- Sensitivity (Trigger) : 0.2 V p-p
- Modes : Single shot, Normal, Auto
- Coupling : AC, DC
- Slope : Rising and falling edge
Others
- Glitch Snare : SCOPE Mode (Component test only)
- Acquire Mode : SCOPE Mode
- Setup memory : 8 Waveform & Setup
- Reference waveform : 51 Waveform and Setup
- Cursor : Time and Volt
- Instrument Setup : Language, Contrast, Graticule
Graphing Multimeter (GMM) Specifications
DC Voltage Measurement
Range |
Resolution |
Accuracy |
500mV |
0.1mV |
±(0.3% Read. + 5dgt) |
5V |
0.001V |
|
50V |
0.01V |
|
600V |
0.1V |
AC Voltage Measurement
Range |
Resolution |
Accuracy |
|
40 Hz – 400 Hz |
400Hz – 20kHz |
||
500mV |
0.1mV |
±(0.5% Read. + 5dgt) |
±(2.5% Read. + 5dgt) |
5V |
0.001V |
||
50V |
0.01V |
||
600V |
0.1V |
AC+DC Voltage Measurement
Range |
Resolution |
Accuracy |
|
40 Hz – 400 Hz |
400Hz – 20kHz |
||
DC 500mV |
0.1mV |
±(0.8% Read. + 5dgt) |
±(3.0% Read. + 5dgt) |
DC 5V |
0.001V |
||
DC 50V |
0.01V |
||
DC 600V |
0.1V |
RPM Measurement
Mode |
Range |
Accuracy |
4 cylinder |
120 – 20000 RPM |
2 RPM |
2 cylinder |
60 – 10000 RPM |
Frequency Measurement
Function |
Range |
Resolution |
Accuracy |
Frequency |
10 Hz |
0.001 Hz |
±(0.1% Read. + 3dgt) |
100 Hz |
0.01 Hz |
||
1 kHz |
0.1 Hz |
||
10 kHz |
1 Hz |
||
100 kHz |
10 Hz |
||
1 MHz |
100 Hz |
||
5 MHz |
1 kHz |
||
% Duty |
2.0 % ~ 98 % |
0.1 % |
Pulse Width > 2µs |
Dwell |
3.6 o ~ 356.4 o |
0.1 o |
1.2 o /krpm + 2 d |
Pulse Width |
2µs ~ 450ms (Pulse Width > 2µs) |
Ohm Measurement
Range |
Resolution |
Accuracy |
500W |
0.1W |
±(0.5% Read. + 5dgt) |
5 kW |
0.001kW |
|
50 kW |
0.01kW |
|
500 kW |
0.1kW |
|
5 MW |
0.001MW |
±(0.75% Read. + 5dgt) |
30 MW |
0.01MW |
±(0.75% Read. + 10dgt) |
Continuity Test
Test Voltage |
Threshold |
Response time |
1.2V |
Approx. 70W |
1 ms |
Diode Test
Range |
Open Circuit Voltage |
Accuracy |
2.0V |
3.0V |
±(2.0% Read. + 5dgt) |
Temperature Measurement
Range |
Resolution |
Accuracy |
-50oC to 1300oC |
0.1 oC |
± 3 oC |
-58oF to 2372oF |
0.1 oF |
± 5.4 oF |
DC Ampere Measurement (Current Probe Output)
Range |
Resolution |
Accuracy |
30 mA – 20 A |
1 mV/10 mA |
±(1.5% Read. + 20 mA) |
100 mA – 40 A |
1 mV/100 mA |
±(2.0% Read. + 20 mA) |
40 A – 60 A |
1 mV/100 mA |
±(4.0% Read. + 0.3 A) |
AC Ampere Measurement (Current Probe Output)
Range |
Resolution |
Accuracy |
|
40 Hz – 1 kHz |
1 kHz – 5 kHz |
||
30 mA – 20 A |
1 mV/10 mA |
±(2.0%Read.+20mA) |
±(4.0%Read.+30mA) |
100 mA – 40 A |
1 mV/100 mA |
±(2.0%Read.+20mA) |
±(6.0%Read.+30mA) |
40 A – 60 A |
1 mV/100 mA |
±(8.0% Read. + 0.3 A) |
General Specifications:
Operation temperature | : | 32 °F to 104 °F (0 °C to 40 °C) |
Storage temperature | : | -4 °F to 140 °F (-20 °C to 60 °C) |
Relative Humidity | : | 0 % to 80 % at 32 °F to 95 °F (0 °C to 35 °C),0 % to 70 % at 32 °F to 131 °F (0 °C to 55 °C). |
Temperature Coefficient | : | Nominal 0.1 x (Specified Accuracy) / °C (< 18 °C or > 28 °C ; < 64 °F or > 82 °F) |
Max Voltage betweenany input and Ground | : | 300 V |
Max Input Voltage | : | 300 V |
GMM Basic DC Accuracy | : | 0.3 % |
Bandwidth | : | DC to 5 MHz (-3dB) |
Max Sample rate | : | 25 Mega sample/second |
Graphing MultimeterDisplay Counter | : | 5,000 count |
Display | : | 280 x 240 pixels (active area) with backlit (EL) |
Reference Waveform | : | 51 Waveform |
PC interface | : | USB version 1.1 |
Power requirements | : | Rechargeable Battery (External AC to DC Power Adaptor) |
Battery Life | : | 4 Hours with backlit off |
Size (H x W x D) | : | 9.06 x 4.72 x 1.97” (230 x 120 x 50 mm) |
Safety & design | : | CAT II 300 V per IEC 1010-1, UL 3111-1 and C22.2 No. 1010-1 |
Accessories:
- Ni-MH Rechargeable Battery(1.2Vx5) Pack - BT10
- Shielded Test Leads (Red, Yellow) - FSTL 1000
- Ground Leads for Shielded Test Leads (Black) - FSTL 1000G
- Alligator Clips (Red, Yellow, Black) - AC5W
- Back Probe Pins (Red, Yellow, Black) - BPP 1000
- 2 mm Adaptors (Red, Yellow, Black) - FSA 2
- Secondary Capacitive Pick-up - SIP 1000
- Ground Leads for Secondary Probe - SIP 1000G
- Inductive Pick-up - RPM 206
- AC to DC Power Adaptor - PA 1000
- Soft Carrying Case - S3C
- User’s Manual (Paper) - FUM 1006
Optional Accessories:
- USB Interface Kit(USB Cable + Firmware Loader Disc) - USB 1000
- Temperature Probe - TP 10
- mA Current Probe - CA113 OS/AT
- Diesel Interface Probe - DPS 1000
- Waveform Manager (CD) - WFM 1000
- Isolated 12 V Charger - PC 1000/12
- Isolated 24 V Charger - PC 1000/24
- User’s Manual (CD) - FUM 1006 CD
Standards:
- CAT II 300V
- IEC 1010-1
- UL 3111-1
- C22.2 No. 1010-1
- UL-Listed
- CE-mark
You may also be interested in the following product(s)
F706 - New Generation Automotive DMM
US$0.00
|
F716 - Dual Display Professional DMM
US$0.00
|