Product information
Details
The 716 automotive multimeters are designed to provide troubleshooting solutions to the most complicated problems encountered with today’s sophisticated automotive electronic systems.
Features:
- 4 4/5 digits, 50000 count (primary) and 9999 count (secondary) dual display with bar-graph. (Frequency range : 99999 counts)
- Closed case calibration through the phototronic serial port.
- Accurate RPM measurements for 2- and 4-stroke automotive engines with 1 to 12 Cylinders using the Inductive Pickup.
- ms-Pulse Width function to test on-time of both PFI type and TBI type fuel injectors, idle air control motors, and electronic transmission controls.
- Duty Cycle and direct DWELL reading for electronic fuel injection, feedback carburetors, and ignition systems.
- 4 steps adjustable triggers on 1 to 12 Cylinders, either 2- or 4-Cycle for outboards, motorcycles and conventional engines.
- Measure temperature of fan switch and catalytic converters up to 2,372 °F (1,300°C).
- O2 Sensor test for a quick diagnosis and simulation of the complete O2 Sensor.
- Ground test to locate bad ground, voltage drops, intermittent connections, or any source of high resistance in an automotive electrical circuits and grounds.
- Charging system test to diagnose the battery and the alternator.
- Battery Drain test to measure the car's battery current when it is turned off.
- Auto Hold, 50 ms high-speed MIN/MAX/AVG, and Relative mode.
- 1 ms peak mode.
- Memory store and recall (20 locations).
- Backlit display.
- Auto-power-off.
- RS-232C phototronic serial port.
- Overmoulded case.
- IEC 1010-1, Cat II 1000V rating.
Accessories:
- Battery’s, 9V (BT1)
- Silicone Test Lead Set (3 colors) (FTL-716)
- Alligator Clips (AC7)
- K-type thermocouple (TP7)
- Inductive Pickup (RPM 206)
- User’s Manual
Optional Accessories:
- RS-232C Interface Cable (RS 70)
- Sample Software Diskette (WS716)
- AC/DC Clamp Adaptor (CA113)
- Capacitance Adaptor (CAP7)
Standards
- UL3111-1
- CSA C22.2 No.1010.1-92
- IEC 1010-1 CATII 1000V
Electrical Specification
Accuracy is given as ±([ % of reading] + [number of least significant digits]), or otherwise specified, at 23°C ± 5°C and less than 80% R.H. for a period of one year after calibration.
DC Voltage Measurement
Range | Resolution | Accuracy | Input Impedance |
500mV | 0.01mV | ±(0.1% Read. + 2dgt) | 10 MW, 30pF nominal (50 MW, 100pF nominal for 500mV range) |
5V | 0.1mV | ||
50V | 1mV | ||
500V | 0.01V | ||
1000V | 0.1V |
NMRR: > 60dB @ 50/60 Hz
CMRR: > 120dB@ DC 50/60 Hz, RS=1kW
AC Voltage Measurement
Range | Resolution | Accuracy | Input Impedance | |
40Hz-400Hz | 400Hz – 2kHz | |||
500mV | 0.01mV | ±(0.5% Read. + 10dgt) | ±(1.0% Read. + 10dgt) | 10 MW, 30pF nominal (50MW, 100 pF nominal for 500 mV range) |
5V | 0.1mV | |||
50V | 1mV | |||
500V | 0.01V | |||
1000V | 0.1V |
CMRR: > 60dB @ DC to 60 Hz, RS = 1 KW
DC Current Measurement
Range | Resolution | Accuracy |
5A | 100µA | ±(0.5% Read. + 10dgt) |
10A | 1mA | ±(0.5% Read. + 20dgt) |
AC Current Measurement (40- 1kHz)
Range | Resolution | Accuracy |
5A | 100µA | ±(0.75% Read. + 10dgt) |
10A | 1mA | ±(1.0% Read. + 20dgt) |
Burden Voltage: 0.03 V/A
Ohms Measurement
Range | Resolution | Accuracy | Open Circuit Voltage |
500Ω* | 0.01Ω |
±(0.1% Read. + 5dgt) | 1.3 V DC |
5 kΩ |
0.1Ω |
±(0.1% Read. + 2dgt) | |
50 kΩ |
1Ω |
||
500 kΩ |
0.01kΩ |
||
5 MΩ |
0.1kΩ |
±(0.3% Read. + 5dgt) | |
50MΩ |
10kΩ |
±(0.75% Read. + 10dgt) |
* Using Relative mode
Diode Tester
Range | Accuracy | Open Circuit Voltage |
2.0V | ±(2.0% Read. + 1dgt) | <3.0 V DC |
Temperature Measurement
Range | Resolution | Accuracy * |
-50°C to 0°C | 0.1°C | ±3.0°C |
0°C to 100°C | ±1.0°C | |
100°C to 1300°C | ±3.0°C | |
-58°F to 32°F | 0.1°F | ±5.0°F |
32°F to 212°F | ±2.0°F | |
212°F to 2372°F | ±5.0°F |
* With “K” Type Thermocouple
Frequency
Range | Resolution | Accuracy |
99.999Hz | 0.001Hz | ±(0.005% Read. + 3dgt) |
999.99Hz | 0.01Hz | |
9.9999kHz | 0.1Hz | |
99.999kHz | 1Hz | |
999.99kHz | 0.01 kHz |
Minimum frequency 0.5 Hz, Sensitivity 250 mV
* Minimum frequency 1 Hz in the Secondary display.
Range | Resolution | Accuracy |
4-stroke | 120-20000 RPM | 2 RPM |
2-stroke | 60-10000 RPM |
RPM (Primary Display)
4 Selectable trigger levels
Range | Resolution | Accuracy |
4-stroke | 240-9999 RPM | 2 RPM |
2-stroke | 120-9999 RPM |
RPM (Secondary Display)
Dwell
Range * | Resolution | Accuracy |
0.0° - 356.4° | 0.1° | 1.2° / krpm + 2dgt |
4 Selectable trigger levels and ± trigger slopes
9 Selectable cylinders 1, 2, 3, 4, 5, 6, 8, 10, 12
* Specified ranges depend on ± trigger slopes, engine rpm
ms-Pulse and Duty cycle
Mode | Range | Accuracy |
Multi-Point-Injection | 0.5 ms—250ms | 0.05ms + 1dgt |
0.0% - 100.0% | 0.04% / krpm +2dgt | |
Single-Point-Injection | 0.5 ms – 250ms | 0.05 ms + 1 dgt |
0.0% - 100.0% | 0.04% / krpm / cyl + 2dgt |
Fuel Injection Detector (Both TBI & PFI)
4 Selectable trigger levels and ± trigger slopes
* Specified ranges depend on ± trigger slopes, engine rpm and number of cylinders
Audible Continuity Test
Audible Threshold | Response Time |
The beeper turns on when the measured resistance is lower than 10 W, and turns of when greater than 70W. | < 200µS |
General Specifications
Display | : | 4 4/5 digits LCD with max. reading of 50000 with 21 segment bar-graph, updates 40 times/sec. |
Polarity | : | Automatic, (-) negative polarity indication. |
Zero adjustment | : | Automatic. |
Over range indication | : | Only the MSD “OL” is displayed. |
Temperature Coefficient | : | Nominal 0.15x (Specified accuracy)/ °C (<18°C or > 28°C) |
Operating Temperature | : | 0°C to 50°C |
Operating Humidity | : | <80% RH |
Storage Temperature | : | -20°C to 60°C |
Altitude | : | 2000m |
Pollution Degree | : | 2 |
Shock & Vibration | : | Per MIL-T28800 for a Class III instrument |
Power | : | Single 9 volt battery NEDA 1604, JIS 006P, IEC6F22. |
Dimension | : | 103 (W) x 208 (H) x 54 (D) mm. |
Weight | : | Approx. 655 g |