Product information
Details
The BS92 is a True-RMS digital power meter including the energy integration function. This user friendly meter has many applications; appliance testing, checking industrial and commercial power systems, plant maintenance and inspection, and electric utility testing, etc.
Features:
- CE-mark Certificated.
- 3 ¾ digits, 4000 count display for power, updates 4 times/sec. (6 digits display for energy integrator.)
- True power, apparent power and reactive power.
- AC to 750kW/kVA/kVAR measurement.
- Power Factor (Cos φ) [0.3 Cap... 1 ... 0.3 Ind] measurement.
- Energy (kWh, kVAh, kVARh) Integrator for maximum 80 hours.
- 3-Phase adaptor (Optional Accessory).
- IEC 1010-1, CATIII600V safety protection.
- Time Stamp for the Energy Integrator.
- True-RMS reading.
- Auto ranging.
- MAX/MIN Record mode.
- Data hold.
- Auto-power-off.
Electrical Specification
Accuracy is given as ± ([% of reading] + [number of least significant digits]) at 18°C to 28°C with relative humidity up to 80%, for a period of one year after calibration. (The accuracy is specified from 5% to 100% of the selected range.)
True Power Measurement
Range | Resolution | Accuracy | Frequency (Hz) | Overload Protection |
400KW | 0.1KW | ±(1.5% Read. + 2dgt) | 45 - 450 | 750V RMS /1000A Peak |
750KW | 1KW |
Apparent Power Measurement
Range | Resolution | Accuracy | Frequency (Hz) | Overload Protection |
400KVA | 0.1KVA | ±(1.5% Read. + 2dgt) | 45 - 450 | 750V RMS /1000A Peak |
750KVA | 1KVA |
Power Factor (Cos φ) Measurement
Range | Resolution | Accuracy | Frequency (Hz) | Overload Protection |
0.3 - 1 | 0.001 | ±(2.0% Read. + 20dgt) | 10 - 60 | 750V RMS /1000A Peak |
Voltage Range : 20V to 750 V RMS
Current Range : 20A to 1000 A Peak
AC Amps
Range | Resolution | Accuracy | Frequency (Hz) | Overload Protection |
400A | 0.1A | ±(1.5% Read. + 2dgt) | 45 - 450 | 1000A Peak |
700A | 1A |
Conversion Type: AC Coupled, True-RMS Measurement
Crest Factor: ≦5
Additional Crest Factor Errors (non-sinusoidal)
Crest Factor | Error (% of reading) |
1 – 3 | 0.5% |
3 – 5 | 3% |
For the continuous waveform of 45Hz to 65 Hz (less than 1000A peak)
AC Voltage Measurement
Range | Resolution | Accuracy | Frequency (Hz) | Overload Protection |
400V | 0.1V | ±(1.0% Read. +3dgt) | 45 - 450 | 750V RMS |
750V | 1V |
Conversion Type: AC Coupled, True-RMS Measurement
Crest Factor ≦5
Additional Crest Factor Errors (non-sinusoidal)
Crest Factor | Error (% of reading) |
1 - 3 | 0.5% |
3 – 5 | 3% |
For the continuous waveform of 45Hz to 65 Hz (less than 750V RMS)
True Power Energy Integrator
Range | Resolution | Accuracy | Frequency (Hz) | Maximum Integration Period |
40000KWh | 0.1KWh | ±(1.5% Read. + 2dgt) | 45 - 450 | 80 hrs. |
75000KWh | 1KWh |
Apparent Power Energy Integrator
Range | Resolution | Accuracy | Frequency (Hz) | Maximum Integration Period |
40000KVAh | 0.1KVAh | ±(1.5% Read. + 2dgt) | 45 - 450 | 80 hrs. |
75000KVAh | 1KVAh |
Reactive Power Energy Integrator
Range | Resolution | Accuracy | Frequency (Hz) | Maximum Integration Period |
40000Kvarh | 0.1Kvarh | ±(4.0% Read. + 2dgt) | 45 - 450 | 80 hrs. |
75000Kvarh | 1Kvarh |
GENERAL
Display 3 ¾ digits, 4000 count display for power, updates 4 times/sec. (6 digits display for energy integrator.)
Operation Temperature 0°C to 45°C
Operation Humidity <80%RH
Storage Temperature -20 ºC to -60 ºC
Altitude 2000m
Pollution Degree 2
Battery Type Single 9V battery, NEDA 1604, JIS 006P or IEC6F22
Battery Life 80 Hrs typical
Maximum Conductor Size 51mm
Maximum Jaw Opening 52mm
Dimension (H x W x D) 245 x 97.5 x 43.9mm
Weight Approx. 545 g (including battery).
Warranty 1 year
Safety Conformance Designed to UL 3111-1, CSA C22.2 No.1010.1-92, and IEC 1010-1 CATIII600V
Standard Equipment Meter, Test leads, instruction manual, 9V battery(installed), and clip-on holster
Accessories:
- Battery, 9V (BT1)
- Test Lead Set (FTL-500)
- Alligator Clips (AC7)
- Clip-on Holster (C130)
- User’s manual
- 3-phase Adapter (PA170) (OPTIONAL)
Standards:
- UL 3111-1
- IEC 1010-1
- CSA C22.2 No.1010.1-92