COMBI419 - Multifunction meter for safety test verifies, automatic tests & use of remote probe

Be the first to review this product

US$0.00

Quick Overview

COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of [environmental parameters (illuminanance, temperature, sound level)à420], leakage currents and [active power, harmonics, power factor measurements on single phase systemsà420]. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu.


Download Specification: COMBI419.pdf

COMBI419 - Multifunction meter for safety test verifies, automatic tests & use of remote probe

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Details

COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of [environmental parameters (illuminanance, temperature, sound level)à420], leakage currents and [active power, harmonics, power factor measurements on single phase systemsà420]. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu.

The instrument permits, moreover, to start principal measures by using a special remote prove (PR400 optional accessory) particular useful to perform tests in very quickly mode and the AUTO internal function to perform sequential measurements of Global Earth Resistance, test on RCDs' and Insulation directly on sockets of civil installations. A contextual help menu selectable by user it's available for each measurement function and permits a valid information during connection of meter to the installation. The newest electronic function selector give to the meter a extreme rugged structure for perfect using "on field". A wide internal memory permits the saving of any measurements and the transfer to PC by serial port with dedicated software it's possible. Each measure can be saved with all the sub-results and test parameters with up to two ID locators (selectable by user on meter) in order to reach the exact point where the measure was performed.

 

Features:

- Continuity test on protective conductor with 200mA

- Insulation resistance 50-100-250-500-1000VDC

- RCDs tripping time and current (general and selective, AC and A types) 10-30-100-300-500mA

- Contact voltage Ut

- Loop impedance P-N, P-P, P-PE

- Loop impedance P-N, P-P, P-PE with high resolution (0.1mΩ) with IMP57 optional accessory

- Prospective short circuit current

- Global earth resistance Ra without RCDs tripping

- Phase sequence

- Leakage current (with HT96U optional accessory)

- AUTOMATIC test (Ra, RCD time, Insulation) directly on outlet

- Using optional remote probe (PR400) for activation of tests

- Noise voltage measure

- Contextual help at display

- Memory and PC interface (Optical-USB)

 

Electrical Specifications:

Accuracy is indicated as ± (% rdgs + no. of dgt) at 23°C ± 5°C, con relative humidity <60%RH

(*) Technical specification can be modified without notice

Continuity test on protective conductors

RangeΩ  ResolutionΩ Accuracy (*) Category of measure
0.00 ~ 9.99 0.01 ±(2.0% rdg + 2dgt) CAT III 240V to GroundCAT III 415V between inputs
10.0 ~ 99.9 0.1
(*) after cable calibration which eliminates the cable resistanceTest current       >200mA DC per R≤5Ω (calibration included)                                                     
current measurement resolution: 1mAOpen leads voltage                                    4 < Vo < 24V

 

RCDs tripping time

Rangems

Resolutionms

Accuracy

Category of measure

½ IDN, IDN

1 ~ 999

1

±(2.0% rdg + 2dgt)

CAT III 240V to GroundCAT III 415V between inputs

2 IDN

1 ~ 200 general1 ~ 250 selective

5 IDN RCD

1 ~ 50  general1 ~ 160 selective

Nominal tripping current                   10mA, 30mA, 100mA, 300mA, 500mA

RCD type                                        AC, A, general and selective

Phase-ground voltage                     100V ÷ 265V

Frequency                                       50Hz ± 0.5Hz, 60Hz ± 0.5Hz

Voltage contact limits                      25V or 50V

 

RCDs tripping current (general, AC and A types)

IDN RCDs type Range IDN (mA) Resolution (mA) Accuracy IDN
IDN £ 10mA AC (0.5 ~ 1.4) IDN 0.1 IDN - 0%, +(5.0% IDN
A (0.5 ~ 2) IDN
IDN > 10mA AC (0.5 ~ 1.4) IDN
A (0.5 ~ 2) IDN

Category of measure                       CAT III 240V to Ground, CAT III 415V between inputs

 

Insulation resistance (DC voltage)

Test voltageV

Range

Resolution

Accuracy

50

0.01 ~ 9.99

0.01

±(2% rdg+2 dgt)

10.0 ~ 49.9

0.1

50.0 ~ 99.9

0.1

±(5% rdg+2 dgt)

100

0.01 ~ 9.99

0.01

±(2% rdg+2 dgt)

10.0 ~ 99.9

0.1

100.0 ~ 199.9

1

±(5% rdg+2 dgt)

250

0.01 ~ 9.99

0.01

±(2% rdg+2 dgt)

10.0 ~ 99.9

0.1

100 ~ 249

1

250 ~ 499

1

±(5% rdg+2 dgt)

500

0.01 ~ 9.99

0.01

±(2% rdg+2 dgt)

10.0 ~ 99.9

0.1

100 ~ 499

1

500 ~ 999

1

±(5% rdg+2 dgt)

1000

0.01 ~ 9.99

0.01

±(2% rdg+2 dgt)

10.0 ~ 99.9

0.1

100 ~ 999

1

1000 ~ 1999

1

±(5% rdg+2 dgt)

Open leads voltage                         1.1 x nominal test voltage

                                                      voltage measurement resolution:1V

Short circuit current                         <3.0mA @ 500V

                                                      <2.0mA @ 50, 100, 250, 1000V

Nominal current                               <2.17mA @ 230kΩ, 500V; 1mA @ 1MΩ, 1000V

Protections                                     the instrument returns an error message while detecting an input voltage >30V

Category of measure                       CAT III 240V to Ground, CAT III 415V between inputs

 

Contact voltage Ut

RangeV ResolutionV Accuracy
0 ~ 2Ut lim 0.1 - 0%, +(2% rdg+2 dgt)

Utlim (Ul)                                         25V, 50V

Category of measure                       CAT III 240V to Ground, CAT III 415V between inputs

 

Loop impedance P-P, P-N, P-PE

Range (Ω)

Resolution (Ω) (*)

Accuracy

0.01 ~ 9.99

0.01

±(5% rdg+2dgt)

10.0 ~ 199.9

0.1

(*) 0.1mΩ in 0.0 ÷ 199.9 mΩ range (with option accessory IMP57)

Maximum peak current                     3.65A @ 127V; 6.64A @ 230V; 11.5A @ 400V

Test voltage                  100÷265V (phase-neutral) / 100÷460V (phase-phase); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz

Category of measure                       CAT III 240V to Ground, CAT III 415V between inputs

 

Global Earth Resistance RA without tripping the RCD

Range (Ω) Resolution (Ω) (*) Accuracy
0.01 ~ 19.99 0.01 ±(5.0%rdg + 1.0Ω)
0.1 ~ 199.9 0.1 ±(5.0%rdg + 10dgt)
1 ~ 1999 1

Test current @ 265V                        <15 mA

Test voltage                                    100÷265V (phase-neutral); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz

Utlim (Ul)                                         25V , 50V

Category of measure                       CAT III 240V to Ground, CAT III 415V between inputs

 

Phase sequence with 1 or 2 wires

Range (V) Results displayed Category of measure
100 ~ 460

"123”→correct phase sequence

"132”→wrong phase sequence

"11-"→phase coincidence

CAT III 240V to Ground

CAT III 415V between inputs

The instrument detects the phase sequence by touching the hot wire. The detection is not performed on insulated cables

Frequency                                       50Hz ± 0.5Hz, 60Hz ± 0.5Hz

 

Leakage current AC TRMS (amperometric input)

RangemV Resolution (mV) Accuracy
1 ~ 1200 1 ±(1.0%rdg + 2dgt)

Frequency range                             50Hz ~ 60Hz

Category of measure                       CAT I 30V to Ground and between inputs

 

 

 

General Specifications:

MECHANICAL FEATURES

Dimensions                                        240 (L) x 160 (W) x 70 (D) mm

Weight (batteries included)               about 1.2kg / (GEO416: about 1kg)

Protection degree                              IP50

 

MEMORY AND SERIAL INTERFACE

Each measurement can be stored

Memory                                          >600 locations

PC communication port                   optical / USB

 

DISPLAY

Features                                         graphic LCD with backlight

GEO416-Visible area                       73x65 mm

GEO416-Low batteries indications    “ ” Symbol at display

 

POWER SUPPLY

Batteries                                         6x 1.5V type LR6, AA, AM3, MN 1500

Battery life                                      > 600 measurements (without using the timer)

 

ENVIRONMENTAL CONDITIONS

Reference temperature of calibration  (23°C ± 5°C)

Working temperature                       0°C ~ 40°C

Working humidity                            < 80%RH

Storage temperature (batteries not included)       -10°C ~ 60°C

Storage humidity                             < 80%RH

 

GENERAL REFERENCE STANDARDS

EMC                                               89/336/EEC guideline amended with 93/68/EEC (IEC61326)

LVD                                                73/23/CEE guideline (IEC61010)

Product guideline                            IEC61557

Insulation                                        class 2 (double insulation)

Pollution degree                              2

Overvoltage category of the voltage inputs (installation/measurement)

CAT III 240V to ground, 415V between inputs

Overvoltage category of the AUX input

5V to ground

Max altitude                                    2000m

 

GENERAL REFERENCE STANDARDS(GEO416)

Safety of measuring instruments      IEC / EN61010-1

Safety of accessories                     IEC / EN61010-031

Product type standard                     IEC / EN61557-1, IEC / EN61557-5

Insulation                                        double insulation

Pollution degree                              2

Overvoltage category                      CAT III 240V to ground, 415V between inputs

Max altitude                                    2000m

EMC                                               EN61326-1(1998) + A1(1999)

 

This instrument complies with the requirements of the European Low Voltage Directives 72/23/CEE (LVD) and EMC 2004/108/CE

Standard Accessoies:

- C2033X: cable 3 wires with Shuko plug

- UNIVERSALKIT: set of 3 cable + 3 alligator clips + 1 test lead

- BORSA75N: carrying bag

- Calibration Certificate ISO9000

- Instruction manual on CD-ROM

- Quick reference guide

 

Optional Accessories:

- HT96U: leakage current clamp 1-100-1000A/1V ? 54mm max diameter

- TOPVIEW2006: Windows software + optical/USB cable

- IMP57: accessory for loop impedance with high resolution

- PR400: remote probe for test activation

 

Standards:

- CE mark

- EN 61557-4 Continuity test

- EN 61557-2 Insulation Resistance

- EN 61010-1

- EN 61557

- EN 61557-3 Loop impedance P-P, P-N, P-PE

- EN 61557-5 Earth resistance

- EN 61557-6 RCD test

- EN 61008

- EN 61009

- EN 61010-032

- EN 61326 EMC Standards

- EN 61036

- 16th edition

 

You may also be interested in the following product(s)

COMBI420 - Multifunction Meter for Safety Tests and Power Measurements on Single Phase Systems

COMBI420 - Multifunction Meter for Safety Tests and Power Measurements on Single Phase Systems

US$0.00
GSC53N - Multifunction Tester and Three-phase Power Analyzer

GSC53N - Multifunction Tester and Three-phase Power Analyzer

US$0.00