COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of [environmental parameters (illuminanance, temperature, sound level)à420], leakage currents and [active power, harmonics, power factor measurements on single phase systemsà420]. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu.
The instrument permits, moreover, to start principal measures by using a special remote prove (PR400 optional accessory) particular useful to perform tests in very quickly mode and the AUTO internal function to perform sequential measurements of Global Earth Resistance, test on RCDs' and Insulation directly on sockets of civil installations. A contextual help menu selectable by user it's available for each measurement function and permits a valid information during connection of meter to the installation. The newest electronic function selector give to the meter a extreme rugged structure for perfect using "on field". A wide internal memory permits the saving of any measurements and the transfer to PC by serial port with dedicated software it's possible. Each measure can be saved with all the sub-results and test parameters with up to two ID locators (selectable by user on meter) in order to reach the exact point where the measure was performed.
Features:
- Continuity test on protective conductor with 200mA
- Insulation resistance 50-100-250-500-1000VDC
- RCDs tripping time and current (general and selective, AC and A types) 10-30-100-300-500mA
- Contact voltage Ut
- Loop impedance P-N, P-P, P-PE
- Loop impedance P-N, P-P, P-PE with high resolution (0.1mΩ) with IMP57 optional accessory
- Prospective short circuit current
- Global earth resistance Ra without RCDs tripping
- Phase sequence
- Leakage current (with HT96U optional accessory)
- AUTOMATIC test (Ra, RCD time, Insulation) directly on outlet
- Using optional remote probe (PR400) for activation of tests
- Noise voltage measure
- Contextual help at display
- Memory and PC interface (Optical-USB)
Electrical Specifications:
Accuracy is indicated as ± (% rdgs + no. of dgt) at 23°C ± 5°C, con relative humidity <60%RH
(*) Technical specification can be modified without notice
Continuity test on protective conductors
Range(Ω) | Resolution(Ω) | Accuracy (*) | Category of measure |
0.00 ~ 9.99 | 0.01 | ±(2.0% rdg + 2dgt) | CAT III 240V to GroundCAT III 415V between inputs |
10.0 ~ 99.9 | 0.1 |
RCDs tripping time
Range(ms) |
Resolution(ms) |
Accuracy |
Category of measure |
|
½ IDN, IDN |
1 ~ 999 |
1 |
±(2.0% rdg + 2dgt) |
CAT III 240V to GroundCAT III 415V between inputs |
2 IDN |
1 ~ 200 general1 ~ 250 selective |
|||
5 IDN RCD |
1 ~ 50 general1 ~ 160 selective |
Nominal tripping current 10mA, 30mA, 100mA, 300mA, 500mA
RCD type AC, A, general and selective
Phase-ground voltage 100V ÷ 265V
Frequency 50Hz ± 0.5Hz, 60Hz ± 0.5Hz
Voltage contact limits 25V or 50V
RCDs tripping current (general, AC and A types)
IDN | RCDs type | Range IDN (mA) | Resolution (mA) | Accuracy IDN |
IDN £ 10mA | AC | (0.5 ~ 1.4) IDN | 0.1 IDN | - 0%, +(5.0% IDN ) |
A | (0.5 ~ 2) IDN | |||
IDN > 10mA | AC | (0.5 ~ 1.4) IDN | ||
A | (0.5 ~ 2) IDN |
Category of measure CAT III 240V to Ground, CAT III 415V between inputs
Insulation resistance (DC voltage)
Test voltage(V) |
Range(MΩ) |
Resolution(MΩ) |
Accuracy |
50 |
0.01 ~ 9.99 |
0.01 |
±(2% rdg+2 dgt) |
10.0 ~ 49.9 |
0.1 |
||
50.0 ~ 99.9 |
0.1 |
±(5% rdg+2 dgt) |
|
100 |
0.01 ~ 9.99 |
0.01 |
±(2% rdg+2 dgt) |
10.0 ~ 99.9 |
0.1 |
||
100.0 ~ 199.9 |
1 |
±(5% rdg+2 dgt) |
|
250 |
0.01 ~ 9.99 |
0.01 |
±(2% rdg+2 dgt) |
10.0 ~ 99.9 |
0.1 |
||
100 ~ 249 |
1 |
||
250 ~ 499 |
1 |
±(5% rdg+2 dgt) |
|
500 |
0.01 ~ 9.99 |
0.01 |
±(2% rdg+2 dgt) |
10.0 ~ 99.9 |
0.1 |
||
100 ~ 499 |
1 |
||
500 ~ 999 |
1 |
±(5% rdg+2 dgt) |
|
1000 |
0.01 ~ 9.99 |
0.01 |
±(2% rdg+2 dgt) |
10.0 ~ 99.9 |
0.1 |
||
100 ~ 999 |
1 |
||
1000 ~ 1999 |
1 |
±(5% rdg+2 dgt) |
Open leads voltage 1.1 x nominal test voltage
voltage measurement resolution:1V
Short circuit current <3.0mA @ 500V
<2.0mA @ 50, 100, 250, 1000V
Nominal current <2.17mA @ 230kΩ, 500V; 1mA @ 1MΩ, 1000V
Protections the instrument returns an error message while detecting an input voltage >30V
Category of measure CAT III 240V to Ground, CAT III 415V between inputs
Contact voltage Ut
Range(V) | Resolution(V) | Accuracy |
0 ~ 2Ut lim | 0.1 | - 0%, +(2% rdg+2 dgt) |
Utlim (Ul) 25V, 50V
Category of measure CAT III 240V to Ground, CAT III 415V between inputs
Loop impedance P-P, P-N, P-PE
Range (Ω) |
Resolution (Ω) (*) |
Accuracy |
0.01 ~ 9.99 |
0.01 |
±(5% rdg+2dgt) |
10.0 ~ 199.9 |
0.1 |
(*) 0.1mΩ in 0.0 ÷ 199.9 mΩ range (with option accessory IMP57)
Maximum peak current 3.65A @ 127V; 6.64A @ 230V; 11.5A @ 400V
Test voltage 100÷265V (phase-neutral) / 100÷460V (phase-phase); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz
Category of measure CAT III 240V to Ground, CAT III 415V between inputs
Global Earth Resistance RA without tripping the RCD
Range (Ω) | Resolution (Ω) (*) | Accuracy |
0.01 ~ 19.99 | 0.01 | ±(5.0%rdg + 1.0Ω) |
0.1 ~ 199.9 | 0.1 | ±(5.0%rdg + 10dgt) |
1 ~ 1999 | 1 |
Test current @ 265V <15 mA
Test voltage 100÷265V (phase-neutral); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz
Utlim (Ul) 25V , 50V
Category of measure CAT III 240V to Ground, CAT III 415V between inputs
Phase sequence with 1 or 2 wires
Range (V) | Results displayed | Category of measure |
100 ~ 460 |
"123”→correct phase sequence "132”→wrong phase sequence "11-"→phase coincidence |
CAT III 240V to Ground CAT III 415V between inputs |
The instrument detects the phase sequence by touching the hot wire. The detection is not performed on insulated cables
Frequency 50Hz ± 0.5Hz, 60Hz ± 0.5Hz
Leakage current AC TRMS (amperometric input)
Range(mV) | Resolution (mV) | Accuracy |
1 ~ 1200 | 1 | ±(1.0%rdg + 2dgt) |
Frequency range 50Hz ~ 60Hz
Category of measure CAT I 30V to Ground and between inputs
General Specifications:
MECHANICAL FEATURES
Dimensions 240 (L) x 160 (W) x 70 (D) mm
Weight (batteries included) about 1.2kg / (GEO416: about 1kg)
Protection degree IP50
MEMORY AND SERIAL INTERFACE
Each measurement can be stored
Memory >600 locations
PC communication port optical / USB
DISPLAY
Features graphic LCD with backlight
GEO416-Visible area 73x65 mm
GEO416-Low batteries indications “ ” Symbol at display
POWER SUPPLY
Batteries 6x 1.5V type LR6, AA, AM3, MN 1500
Battery life > 600 measurements (without using the timer)
ENVIRONMENTAL CONDITIONS
Reference temperature of calibration (23°C ± 5°C)
Working temperature 0°C ~ 40°C
Working humidity < 80%RH
Storage temperature (batteries not included) -10°C ~ 60°C
Storage humidity < 80%RH
GENERAL REFERENCE STANDARDS
EMC 89/336/EEC guideline amended with 93/68/EEC (IEC61326)
LVD 73/23/CEE guideline (IEC61010)
Product guideline IEC61557
Insulation class 2 (double insulation)
Pollution degree 2
Overvoltage category of the voltage inputs (installation/measurement)
CAT III 240V to ground, 415V between inputs
Overvoltage category of the AUX input
5V to ground
Max altitude 2000m
GENERAL REFERENCE STANDARDS-(GEO416)
Safety of measuring instruments IEC / EN61010-1
Safety of accessories IEC / EN61010-031
Product type standard IEC / EN61557-1, IEC / EN61557-5
Insulation double insulation
Pollution degree 2
Overvoltage category CAT III 240V to ground, 415V between inputs
Max altitude 2000m
EMC EN61326-1(1998) + A1(1999)
This instrument complies with the requirements of the European Low Voltage Directives 72/23/CEE (LVD) and EMC 2004/108/CE
Standard Accessoies:
- C2033X: cable 3 wires with Shuko plug
- UNIVERSALKIT: set of 3 cable + 3 alligator clips + 1 test lead
- BORSA75N: carrying bag
- Calibration Certificate ISO9000
- Instruction manual on CD-ROM
- Quick reference guide
Optional Accessories:
- HT96U: leakage current clamp 1-100-1000A/1V ? 54mm max diameter
- TOPVIEW2006: Windows software + optical/USB cable
- IMP57: accessory for loop impedance with high resolution
- PR400: remote probe for test activation
Standards:
- CE mark
- EN 61557-4 Continuity test
- EN 61557-2 Insulation Resistance
- EN 61010-1
- EN 61557
- EN 61557-3 Loop impedance P-P, P-N, P-PE
- EN 61557-5 Earth resistance
- EN 61557-6 RCD test
- EN 61008
- EN 61009
- EN 61010-032
- EN 61326 EMC Standards
- EN 61036
- 16th edition