Product information
Details
The BS8000DTB (Double Time Base) series has two individual base with a 1mV high vertical amplifier sensitivity. User can use a Zoom display to hold up the second sweep signal thanks to the separate second time base capability. The 2 channel 4 traces display, trigger level lock function and the use of digital control switch are making this series much value added to its’ competitors in the marker.
Feature:
- High Sensitivity (1mV/Div)
- Digital Code Switch
- B (delay) sweep expand any time segment of A sweep (main)
- B sweep zoom display of view signal
- CE Approved, CATII 600V CE-EMC & LVD
Specifications
Vertical System
Sensitivity | 1mV/DIV ~ 5V/DIV ±5% (1mV ~ 2mV± 8%),1-2-5 step, 12 calibrated steps | ||
Bandwidth(-3dB) | 5mV ~ 5V/DIV | DC ~ 40MHz | |
1mV ~ 2mV/DIV | DC ~ 15MHz | ||
Rise Time | 5mV ~ 5V/DIV | Approx 8.8ns | |
1mV ~ 2mV/DIV | Approx 23ns | ||
Overshot | ≦5% | ||
Damp | ≦5% | ||
Input Impedance | 1MW ± 2%, 27ρF (direct), 1MW± 5%, 17ρF (by probe) |
||
Maximum Input Voltage | 400V (DC + AC peak, direct), 400V(DC + AC peak, by probe) |
||
Operation Mode | CH1, CH2, ALT, CHOP, ADD, DUAL, X-Y | ||
Coupling Mode | AC, GND, DC | ||
Slope Inverting | CH2 Only |
Trigger System
Trigger Sensitivity | Frequency | INT | EXT |
DC – 40MHz | 2 DIV | 200mV | |
Ext. Trigger Input Impedance | 1MW ± 2%, approx 35ρF | ||
Ext. Trigger Maximum Input Voltage | 100V (DC+AC peak) | ||
Trigger Sources | CH1, CH2, LINE, ALT, EXT | ||
Trigger Mode | NORM, AUTO, SINGLE | ||
Coupling | AC, HF REJ, TV, DC | ||
Slope | +/- |
Horizontal System
Sweep Mode | A, A INT, B, B TRIG’D |
A Time-base | 0.1μs to 0.5s/DIV ± 5%, in 21 calibrated steps (1-2-5seq) |
Sweep Var. | ≧2.5:1, adjustable continuously |
Hold-off | Can hold off more than 8 times of the minimum sweep suspension and can be adjusted continuously |
B Time-base | 0.1μs to 5ms/DIV ± 5%, in 12 calibrated steps (1-2-5seq) |
Delay time | 1μs to 5ms/DIV can be adjusted continuously |
Delay shaking ratio | ≦1:10000 |
CH1 Output
Output Voltage | 100mV/DIV or 50mV/DIV INTO 50Ω |
Output Impedance | Approximately 50Ω |
X-Y Mode
Sensitivity | Same as the vertical system |
Input Impedance | 1MW ± 2%, 27ρF (direct),1MW± 5%, 17ρF (by probe) |
Bandwidth (-3dB) | DC: DC ~ 2MHz |
X-Y Phase Difference | ≦ 3° (DC ~ 100kHz) |
Z Axis System
Input Signal | ± 5V (NEGATIVE INCREASES INTENSITY) |
Band Width | DC ~ 5MHz |
Maximum Input Voltage | 50V (DC + AC peak), MAX AC 1kHz |
Calibration Signal
Waveform |
Symmetric Square Wave |
Amplitude |
2Vp-p ±2% |
Frequency |
1kHz ±2% |
CRT
Display Area |
8 x 10DIV 1DIV=10mm |
Display Color |
Green |
Power Source
Voltage Range | 230V ±10% |
Frequency | 50Hz ±2Hz |
Power Consumption | 45W |
Physical Features
Weight | 8kgs |
Dimensions | 150H x 310W x 440D mm3 |
Working Environment
Working Temperature | 0°C ~ 40°C |
Working Humidity | 85% |
Storage Temperature | -10°C ~ 60°C |
Storage Humidity | 70%RH |