BSTCALTEK

Product information

BS8040DTB - 40MHz Double Time-Base Oscilloscope

Be the first to review this product

US$0.00

Quick Overview

The BS8000DTB (Double Time Base) series has two individual base with a 1mV high vertical amplifier sensitivity. User can use a Zoom display to hold up the second sweep signal thanks to the separate second time base capability. The 2 channel 4 traces display, trigger level lock function and the use of digital control switch are making this series much value added to its’ competitors in the marker.


Download Specification: BS8040DTB.pdf

BS8040DTB - 40MHz Double Time-Base Oscilloscope

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Details

The BS8000DTB (Double Time Base) series has two individual base with a 1mV high vertical amplifier sensitivity. User can use a Zoom display to hold up the second sweep signal thanks to the separate second time base capability. The 2 channel 4 traces display, trigger level lock function and the use of digital control switch are making this series much value added to its’ competitors in the marker. 

 

Feature:

Ÿ- High Sensitivity (1mV/Div)

Ÿ- Digital Code Switch

Ÿ- B (delay) sweep expand any time segment of A sweep (main)

Ÿ- B sweep zoom display of view signal

Ÿ- CE Approved, CATII 600V CE-EMC & LVD

 

 

Specifications

Vertical System

Sensitivity 1mV/DIV ~ 5V/DIV ±5% (1mV ~ 2mV± 8%),1-2-5 step, 12 calibrated steps
Bandwidth(-3dB) 5mV ~ 5V/DIV DC ~ 40MHz
1mV ~ 2mV/DIV DC ~ 15MHz
Rise Time 5mV ~ 5V/DIV Approx 8.8ns
1mV ~ 2mV/DIV Approx 23ns
Overshot ≦5%
Damp ≦5%
Input Impedance 1MW ± 2%, 27ρF (direct),
1MW± 5%, 17ρF (by probe)
Maximum Input Voltage 400V (DC + AC peak, direct),
400V(DC + AC peak, by probe)
Operation Mode CH1, CH2, ALT, CHOP, ADD, DUAL, X-Y
Coupling Mode AC, GND, DC
Slope Inverting CH2 Only

 

Trigger System

Trigger Sensitivity Frequency INT EXT
DC – 40MHz 2 DIV 200mV
Ext. Trigger Input Impedance 1MW ± 2%, approx 35ρF
Ext. Trigger Maximum Input Voltage 100V (DC+AC peak)
Trigger Sources CH1, CH2, LINE, ALT, EXT
Trigger Mode NORM, AUTO, SINGLE
Coupling AC, HF REJ, TV, DC
Slope +/-


Horizontal System

Sweep Mode A, A INT, B, B TRIG’D
A Time-base 0.1μs to 0.5s/DIV ± 5%, in 21 calibrated steps (1-2-5seq)
Sweep Var. ≧2.5:1, adjustable continuously
Hold-off Can hold off more than 8 times of the minimum sweep suspension and can be adjusted continuously
B Time-base 0.1μs to 5ms/DIV ± 5%, in 12 calibrated steps (1-2-5seq)
Delay time 1μs to 5ms/DIV can be adjusted continuously
Delay shaking ratio ≦1:10000

 

CH1 Output

Output Voltage 100mV/DIV or 50mV/DIV INTO 50Ω
Output Impedance Approximately 50Ω

 

X-Y Mode

Sensitivity Same as the vertical system
Input Impedance 1MW ± 2%, 27ρF (direct),1MW± 5%, 17ρF (by probe)
Bandwidth (-3dB) DC: DC ~ 2MHz
X-Y Phase Difference ≦ 3° (DC ~ 100kHz)

 

Z Axis System

Input Signal ± 5V (NEGATIVE INCREASES INTENSITY)
Band Width DC ~ 5MHz
Maximum Input Voltage 50V (DC + AC peak), MAX AC 1kHz

 

Calibration Signal 

Waveform

Symmetric Square Wave

Amplitude

2Vp-p ±2%

Frequency

1kHz ±2%

 

CRT

Display Area

8 x 10DIV  1DIV=10mm

Display Color

Green

 

Power Source

Voltage Range 230V ±10%
Frequency 50Hz ±2Hz
Power Consumption 45W

 

Physical Features

Weight 8kgs
Dimensions  150H x 310W x 440D mm3

 

Working Environment

Working Temperature 0°C ~ 40°C
Working Humidity 85%
Storage Temperature -10°C ~ 60°C
Storage Humidity 70%RH

 

Product Tags